- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources2
- Resource Type
-
0000000002000000
- More
- Availability
-
20
- Author / Contributor
- Filter by Author / Creator
-
-
Albuquerque, I. F. (2)
-
Alexander, T. (2)
-
Alton, A. K. (2)
-
Ave, M. (2)
-
Back, H. O. (2)
-
Batignani, G. (2)
-
Biery, K. (2)
-
Bocci, V. (2)
-
Bottino, B. (2)
-
Bussino, S. (2)
-
Cadeddu, M. (2)
-
Cadoni, M. (2)
-
Calaprice, F. (2)
-
Caminata, A. (2)
-
Canci, N. (2)
-
Caravati, M. (2)
-
Carpinelli, M. (2)
-
Catalanotti, S. (2)
-
Cataudella, V. (2)
-
Cavalcante, P. (2)
-
- Filter by Editor
-
-
null (1)
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
null (Ed.)DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV/c2 mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to about 180 eVer, exploiting 37Ar and 39Ar decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Moreover, we present the determination of the ionization response to nuclear recoils down to ∼ 500 eVnr , the lowest ever achieved in liquid argon, using in situ neutron calibration sources and external datasets from neutron beam experiments.more » « less
-
Agnes, P.; Albuquerque, I. F.; Alexander, T.; Alton, A. K.; Araujo, G. R.; Asner, D. M.; Ave, M.; Back, H. O.; Baldin, B.; Batignani, G.; et al (, Physical Review Letters)
An official website of the United States government

Full Text Available